L'explication/l'anotation:For anti-intrusion systems.
La description détaillée de marque:The probes on the basis of hermetic contacts (sealed-contact reed relays) the pillar stands to
effect of external factors, are workable over a wide range of
temperatures, moisture, pillar stand to effect chemically active substances
and dust.
the hermetic electric contact provides the protection in
dangerous in respect of explosion and inflammable environments.
the overall dimensions (refer to image)
(a) the overall picture of, the MM 67
(b) the maximal length of glass, MM 28
(c) the maximal diameter of glass, MM 5 , 3
(d) the conclusion diameter, MM 1
(g) design 15, 8
Electrical characterizations
maximal the switching power, computer engineering 30
maximal switching current, and 1
maximal the switched voltage, in 200
transition the R, do not More than, Omagh 0, 15
breakdown point, no less than, in 350
R insulation, no less than, Omagh 10**9
magnetic characteristics
operation ampere-turn, AW 45 - 90
resetting ratio 0, 35 - 0, 9
maximal response time, incineration facility 1, 5
maximal dropout time, incineration facility 2, 5
maximal working frequency, Hz 50 |