Aclaración/resumen:Manometric. To the operation in piezoelectric resonant sensors absolute. pressure
with frequency output. Right-angled quartz. body.
clearances: ÐÊÌÀ-Ð-1 (3; 4) - 25õ23õ3, 0-6, 1ìì; ÐÊÌÀ-Ð-2. 11õ12õ2, 74ìì
Descripción completa de la marca:The standard number of is issued: ÐÊÌÀ-Ð-1 ÐÊÌÀ-Ð-2 ÐÊÌÀ-Ð-3 ÐÊÌÀ-Ð-4.
interval of working pressures of ÐÊÌÀ-Ð-1 3; 4). From 0 to 60 MPa;
ÐÊÌÀ-Ð-2. From 0, 05 to 0, 12 MPa;
nominal vibration velocity of resonators of Fn. From 32 to 48 kHz;
dynamic resistance of Rê. 200 lumps;
capacity, scattering on resonators of W. 4 microWatts;
dynamic characteristics f (P) = F0 + A1P + A2P2 + A3P3,
where f (P) - resonator frequency in case of running value of pressure, Hz ;
F0- resonator frequency in case of zero-point pressure, Hz;
r - running value of pressure, MPa;
À2, À3- coefficients of second and third order. They determine
the non-linearity (the value of which - less 0, 4 %) and are specified in case of order.
sensibility (linear coefficient of À1. From 58, 76 to 25000 Ãö/Ìïà;
operating temperature range. From - 40 to + 80 hails with;
temperature error on some interval of working òåìï-òóð not more 0, 75%
vibration proofness (of 10 to 2000 Hz, acceleration 50 ì/ñ2, 8 o'clock).
+/- 5 ððì;
the relative deviation of linear coefficient of À1 from its middle
significance (is recalled in case of order). From +/- 5 to +/- 20 %;
hysteresis of working áàðî÷àñòîòíîé characteristic not more. 0, 02 %;
ageing: for first year of storage not more. +/- 5 ððì;
in years that followed not more. +/- 25 ððì;
the dependence of resonator frequency from temperature of f= f0+A1T+A2T2
âîñïðîèçâîäèìà with precision. 0, 05 %;
the resonators are products unrestorable and repair not
are subject to. The maker guarantees the adequacy in quality of resonator in case of
observance by the conditions consumer of transportation, storage and
operation. Guarantee period - 50000 ch from the day of input
resonators in operation. Guarantee storage life - ten years with
time of manufacture. The maker guarantees the coefficient change
resonators transformation to its initial value +/- 0. 05 %
for the first year and +/- 0. 02 % in the year that followed.
for indemnification of temperature error, is being applied
the thermosensitive crystal resonator ÐÊÒ206.
the operating temperature range can be extended from - 269 to +250 the hail with
(is recalled in case of order). On the basis of ÐÊÌÀ have been developed the probes
absolute pressure (with indemnification of temperature error)
quality class to 0, 05. |